Model No: T.49B
- Best Quality
- Affordable Pricing
- On-Time Delivery
- Customer Satisfaction
L - Oblique Angle Plate 03 Head Hole - 120° - L/R (Titanium) Introduction, Features, Benefits, Indications, Precautions, Warnings and Surgical Technique
The goal of using the L – Oblique Angle Plate 03 Head Hole – 120° – L/R (Titanium) in surgery for broken bones is to put the bones back together correctly and make them work properly.
As per the AO (a well-known medical body), internal fixation is characterized by achieving proper bone alignment, secure fixation, maintaining adequate blood flow, and encouraging early, active movement.
L - Oblique Angle Plate 03 Head Hole - 120° - L/R (Titanium) Features and Benefits
- Numerous geometries, sizes, and strengths of L – Oblique Angle Plate 03 Head Hole – 120° – L/R (Titanium) are available
- Seven screw diameters to choose from: 1.5 mm, 2 mm, 2.5 mm, 2.8 mm, 2 mm Locking, 2.5 mm Locking and 2.8 mm Locking
- Plates have smooth edges to avoid irritating soft tissues when needed
- We have thinner plates and screws where appropriate
- Emergency screws are available for each screw size, just in case
- Both plates and screws are made from pure, strong Titanium
- We use the same tools for all of them, which makes things easier
- These special plates make things stable, reduce the risk of screws coming loose, and mean less need for precise plate shaping, lowering the risk of damaged screws
L - Oblique Angle Plate 03 Head Hole - 120° - L/R (Titanium) Indications
When it comes to selective trauma in the midface and craniofacial skeleton, craniofacial surgery, reconstructive procedures, and selective orthognathic surgery involving the maxilla and chin, this plate is the intended tool for the job.
Specifications
Product Video
Specifications
‘L’ – Plate 1.5mm Oblique Angle 03 Hole – Right (Titanium) |
---|
TITANIUM CODE | SIZE |
---|---|
T.49B.15.05-R | 3 Head Holes – 120° – 2 Holes |
T.49B.15.06-R | 3 Head Holes – 120° – 3 Holes |
‘L’ – Plate 1.5mm Oblique Angle 03 Hole – Left (Titanium) |
---|
TITANIUM CODE | SIZE |
---|---|
T.49B.15.05-L | 3 Head Holes – 120° – 2 Holes |
T.49B.15.06-L | 3 Head Holes – 120° – 3 Holes |
‘L’ – Plate 2.0mm Angle 3 Hole – Right (Titanium) |
---|
TITANIUM CODE | SIZE |
---|---|
T.49B.20.05-R | 3 Head Holes – 120° – 2 Holes |
T.49B.20.06-R | 3 Head Holes – 120° – 3 Holes |
‘L’ – Plate 2.0mm Angle 3 Hole – Left (Titanium) |
---|
TITANIUM CODE | SIZE |
---|---|
T.49B.20.05-L | 3 Head Holes – 120° – 2 Holes |
T.49B.20.06-L | 3 Head Holes – 120° – 3 Holes |
‘L’ – Plate 2.5mm Angle 3 Hole – Right (Titanium) |
---|
TITANIUM CODE | SIZE |
---|---|
T.49B.25.05-R | 3 Head Holes – 120° – 2 Holes |
T.49B.25.06-R | 3 Head Holes – 120° – 3 Holes |
‘L’ – Plate 2.5mm Angle 3 Hole – Left (Titanium) |
---|
TITANIUM CODE | SIZE |
---|---|
T.49B.25.05-L | 3 Head Holes – 120° – 2 Holes |
T.49B.25.06-L | 3 Head Holes – 120° – 3 Holes |
Product Video
Maxillofacial Instrumentation

Maxillofacial Instruments |
---|
Reference No | Instrumentations |
---|---|
MX-INS-01 | Bone Holding Forcep (Pair) |
MX-INS-02 | 1.5mm Screw Driver With Holding Sleeve |
MX-INS-03 | 2.0mm Screw Driver With Holding Sleeve |
MX-INS-04 | 2.5mm Screw Driver With Holding Sleeve |
MX-INS-05 | Screw Driver Handle with Quick Coupling |
MX-INS-06 | Maxillofacial Plate Bending Forcep |
MX-INS-07 | Maxillofacial Modeling Lever |
MX-INS-08 | Maxillofacial Plier |
MX-INS-09 | Depth Gauge For Maxillofacial Screw |
MX-INS-10 | 6mm Hohmann Retractor For Maxillofacial |
MX-INS-11 | 8mm Hohmann Retractor For Maxillofacial |
MX-INS-12 | 1.5/2.0 mm Maxillofacial Trocar Sleeve |
MX-INS-13 | Maxillofacial Plate Holding Forcep |
MX-INS-14 | 1.2mm Drill Bit 4″ |
MX-INS-15 | 1.5mm Drill Bit 4″ |
MX-INS-16 | 1.8mm Drill Bit 4″ |
MX-INS-17 | Maxillofacial Instrument Box |
MX-INS-18 | Screw Holding Forcep |
MX-INS-19 | Maxillofacial Plate Cutter |
MX-INS-20 | Maxillofacial Plate Tray |
MX-INS-21 | Maxillofacial Screw Tray with Implant Box |
MX-INS-22 | Maxillofacial Instrument Box |