Model No:
- Best Quality
- Affordable Pricing
- On-Time Delivery
- Customer Satisfaction
Specification for 2.7 mm Locking Volar Juxta-Articular Distal Radius Plate 5 Head Holes
- There are 3, 4, and 5 available hole plate options.
- There are Left and Right plates available.
- Titanium and stainless steel versions are readily available.
- Closing Width: 2.7 mm Radius of the Distal Volar Articulation The plate has already been contoured to fit the volar surface of the distal radius, so no further shaping is required. Complex fractures may benefit from the use of juxta-articular plates. The radius is positioned as far away from the elbow as possible. The plate’s locking holes are slanted 5 degrees away from the articular surface in the head, facilitating a distal plate insertion.
- The radial styloid is affixed to a temporary K-wire fixation with the help of straight plates that are shaped to fit the radial column and have a notched tip.
- To better conform to the distal radius’s anatomy and reduce the risk of soft tissue irritation, the plate head features undercuts on the underside.
- This plate features both combination and round holes. Fixation with locking screws in the threaded section and compression with cortex screws in the dynamic compression unit section are both possible thanks to the combi holes.
- Locking screws of 2.7 mm in diameter can be used in the threaded section of the shaft, and cortical screws of the same diameter can be used in the compression section. All you need are 2.7 mm locking screws to secure the plate’s head into place.
- Plates make it possible to place implants according to each patient’s unique fracture pattern.
- Because there is less bone touching the plate, the periosteal blood supply is less likely to be compromised.
- The need to cut plates is eliminated when a variety of plate lengths are available for selection.
- Anatomically correct pre-contoured plate.
- Tendon and soft tissue irritation is reduced by the low plate and screw profile.
- Rounded edges reduce the likelihood of tendon adhesion.
- There is less overall implant bulk thanks to the use of smaller plates and screws to treat individual fracture fragments.
- To stabilise the articular surface, lessen the need for bone graft, and achieve fixation in osteoporotic bone, a fixed-angle construct using locking screws is an attractive option.
- By preventing screws from backing out and the resulting loss of reduction, a locking plate improves the structural integrity of the assembly. In addition, there is less of a chance of the screw holes being stripped and less precise anatomic plate contouring is required.
- For use with the 2.7 mm Locking Volar Juxta Articular Distal Radius Plate, a Full Instrument Set is also available. This plate can be bent with a plate bending press, held with plate holding forceps, bent with plate bending pliers, used to elevate bones, cut bones, nibble bones, measure depth, and drive screws or trocar sleeves, among other general instruments.
uses of 2.7 mm Locking Volar Juxta-Articular Distal Radius Plate 5 Head Holes
- Complex distal radius intra- and extra-articular fractures and osteotomies can be fixed with a 2.7 mm Locking Volar Juxta Articular Distal Radius Plate.
Instruments set of 2.7 mm Locking Volar Juxta-Articular Distal Radius Plate 5 Head Holes
Distal Radius Plates Instruments Set
Below are list of items in 2.7 mm Locking Volar Juxta-Articular Distal Radius Plate 5 Head Holes Instruments Set.
- 2.4 mm Threaded Drill Guide for 1.8 mm Drill Bit
- 2.7 mm Threaded Drill Guide for 2 mm Drill Bit
- Counter Sink Copuling Shaft
- Depth Gauge for 2 / 2.4 mm Screws
- Depth Gauge for 2.7 mm Screws
- Double Drill Sleeve (Universal Drill Sleeve) 1.8/2.4 mm
- Double Drill Sleeve (Universal Drill Sleeve) 2.0/2.7 mm
- Drill Bit 1.8 x 100 mm, Quick Coupling
- Drill Bit 2 x 100 mm, Quick Coupling
- Drill Bit 2.4 x 100 mm, Quick Coupling
- Drill Bit 2.7 x 100 mm, Quick Coupling
- Hohmann Recator 6 mm
- Kirschner Wire 1.8 x 150 mm
- Plate Bender
- Periosteal Elevator Fiber Handle
- Plate and Bone Holding Forceps Ratchet Lock-Type1
- Plate and Bone Holding Forceps Ratchet Lock-Type2
- Reduction Forcep Pointed Tip Ratchet Lock
- Reduction Forcep Serrated Tip Ratchet Lock
- Screw Driver Hexagonal, Holding Sleeve, for 2.7 mm Locking Screws
- Screw Driver Torque for 2.4/2.7 mm Locking Screws
- Screw Driver Quick Coupling for 2.7 mm Locking Screws
- Sharp Hook
- T Handle Quick Coupling
- Tap for 2.4 mm Screws, Quick Coupling
- Tap for 2.7 mm Screws, Quick Coupling
- Graphics Aluminum Box with Silicone Fittings
Specifications
Product Video
Specifications
| 2.7 mm Locking Volar Juxta-Articular Distal Radius Plate 5 Head Holes |
|---|
Product Video