Model No:
Nail Diameter: 9 mm to 14 mm
Nail Length: 280 mm to 460 mm
TYPE: SS/TT
- Best Quality
- Affordable Pricing
- On-Time Delivery
- Customer Satisfaction
Specification for Femoral Reconstruction Nail
- sophisticated nail art
- Design of the Femoral Reconstruction Nail allows for a lot of flexibility.
- Different femur nails on the left and right
- Easy insertion and extraction thanks to anatomical bend
- All nails are cannulated in a guided insertion technique using reamed and unreamed edges.
- Large portfolio with nails ranging in size from 9 to 14 mm in diameter and 280 to 460 mm in length
- Static, dynamic, and standard locking with a flexible locking configuration
- Titanium and SS 316L are both available for the femoral reconstruction nail.
- distinct options for distal locking
- Every anatomical circumstance and fracture type can be locked in place optimally thanks to the special distal combination hole. Standard locking (with two locking screws) is an option for the surgeon. In both configurations, the end cap enables angular stable locking of the most distal locking implant.
- apex caps
- Screwdriver with self-retaining mechanism for quick and secure end cap insertion
- Blocking the most proximal locking screw would ensure complete angular stability.
- End caps make it easier to remove nails and stop tissue from growing in.
- security screws
- The 6.4 mm Cannulated Lag Screws have an exceptional grip thanks to their distinctive thread design. Thinner flanks and improved front cutting flutes allow for less insertion torque and less bone removal.
- Due to the space between the two 6.4 mm lag screws and the separation between them, secure placement of the lag screws within small neck diameters is possible.
- The round and oblong holes in the distal locking configuration allow for static and/or dynamic distal locking.
- The Femoral Reconstruction Nails all share 5 mm cortical screws, which are intended to simplify surgery and encourage a minimally invasive approach.
- Self-holding screwdriver for quick and safe picking up of locking screws.
- a double thread for more points of contact and greater stability
- improved mechanical resistance through a larger cross-section
- a thread that is nearer the screw head offers better bone traction and increased stability.
- Self-holding screwdriver for quick and secure picking up of locking screws
Uses of Femoral Reconstruction Nail
- The Femoral Reconstruction Nail System is used to treat growth plate-fused fractures in adults and adolescents. The system’s indications go as follows:
- fractures in the scrotum
- Neck/shaft fractures on opposite sides
- Broken femoral shaft
- Pathologic fractures on the horizon
- Incorrect and absent unions
- Femoral Replacement Using Nails
- Femoral Replacement Contraindications for nails
- To select the most suitable device and treatment, one must rely on the physician’s education, training, and professional judgment. Conditions that increase the likelihood of failure include:
- any infection, whether latent or active, or any obvious local inflammation in or near the affected area.
- compromised vascularity that would prevent the fracture or the surgical site from receiving enough blood.
- bone stock that has been damaged by illness, infection, or previous implantation and cannot support or fix the devices properly.
- sensitive material, whether known or suspected.
- Obesity. A patient who is obese or overweight can place loads on the implant that could cause the device’s fixation to fail or the device itself to malfunction.
- Patients with insufficient tissue over the surgical site.
- Using implants in a way that could affect how well certain bodily functions or structures work.
- any mental or neuromuscular condition that poses an unacceptably high risk of fixation failure or postoperative complications.
- Other medical or surgical issues that would prevent surgery’s potential benefits.
Specifications
Product Video
Specifications
| Femoral Reconstruction Nail |
|---|
Product Video